EMC Lab

Every electronical device needs to be tested for its EMC compliance before it can be put on the market. Only products that work in accordance with existing law can be assigned the CE-label

Competent personnel helps with measurements during the development process. The lab is not accredited but can offer inspection according to the testing standards listed below.

Measurement Valley's working group R&D supports all members in all EMC questions. To facilitate easy implementation of regulations concerning noise immunity and transient emission, Sartorius' EMC Lab offers cost-efficient EMC measurements.

Testing Standards

Noise Immunity

Phänomen Prüfnorm Prüfpegel
Entladung Statischer Elektrizität (ESD) EN 61000-4-2 bis 16,5kV
Elektromagnetisches HF-Feld (80 MHz - 4 GHz) EN 61000-4-3 3 und 10V/m
Schnelle transiente Störgrößen (Burst) EN 61000-4-4 bis 4kV
Stoßspannungen (Surge) EN 61000-4-5 bis 4kV
geleitete Hochfrequenz (150 kHz - 80 MHz) EN 61000-4-6 3 und 10V
Magnetfelder mit energietechnischen Frequenzen 50Hz EN 61000-4-8 30A/m
Spannungsvariationen (Einbrüche, Schwankungen, etc.) EN 61000-4-11 100-240VAC

Transient Emission

Phänomen Prüfnorm Informationen
Störaussendung Gehäuse EN 55022 und EN 55011 Klasse A und B
Leitungsgebundene Störspannungen (150 kHz-30MHz) EN 55022 und EN 55011 Klasse A und B 

Contact

Anschrift

Herr Carsten Dunkel
Sartorius AG
Tel.: 0551 / 308 3131
Fax: 0551 / 308 3652

 